Published 1987 | Version v1
Journal article

Optimization of detector shield shape in radiometric testing of thick-walled products

Description

To calculate geometrical parameters of a collimation device of radiometric defectoscopes designed for testing of thick-walled products, angular and energy distributions of a point isotropic gamma source radiation field in the detection area behind an infinite barrier simulating a tested item have been studied. Dry concrete was used as a barrier in calculations and water - during experimental test. Results of calculation of the detector shield thickness are given

Additional details

Additional titles

Original title (Russian)
Оптимизация формы защиты детектора при радиометрическом контроле толстостенных изделий

Publishing Information

Journal Title
Defektoskopiya
Journal Issue
no.1
Series
Defektoskopiya.
ISSN
0130-3082
CODEN
DEFKA

Optional Information

Notes
For English translation see the journal Soviet Journal of Nondestructive Testing (USA).