Published October 1978 | Version v1
Journal article

Analytical calculations of some ion-implantation depth distributions

  • 1. Atomic Energy of Canada Ltd., Chalk River, Ontario. Chalk River Nuclear Labs.

Description

Power-law range, damage, and ionization distributions are calculated analytically in the path-length approximation for the equal-mass case. An analytical expression is given for the asymptotic (large-depth) behaviour of the distributions, and the form of the small-depth behaviour is given. Also, the entire distribution is calculated as an inverse Mellin transform, both by numerical integration and by a numerical application of the stationary-phase method. The asymptotic expression is useful only in the extreme tail of the distribution, the numerical integration is generally valid, and the numerical stationary-phase method is useful except at very small depths. Results are shown for the power parameter m = 0.055, 0.311 and 0.48. (author)

Additional details

Publishing Information

Journal Title
Radiat. Eff.
Journal Volume
39
Journal Issue
1
Series
Radiat. Eff.
Journal Page Range
39-44
ISSN
0033-7579

INIS

Country of Publication
United Kingdom
Country of Input or Organization
United Kingdom
INIS RN
10471590
Subject category
S75: CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND SUPERFLUIDITY;
Resource subtype / Literary indicator
Numerical Data
Descriptors DEI
GRAPHS; ION IMPLANTATION; IONIZATION; MATHEMATICAL MODELS; PHYSICAL RADIATION EFFECTS; RANGE; SPATIAL DISTRIBUTION; THEORETICAL DATA
Descriptors DEC
DATA; DATA FORMS; DISTRIBUTION; INFORMATION; NUMERICAL DATA; RADIATION EFFECTS