Published September 1995
| Version v1
Report
Present status of the NIRS-ECR ion source for the HIMAC
Creators
- 1. National Inst. of Radiological Sciences, Chiba (Japan)
Description
The present status of NIRS-ECR ion source for the Heavy Ion Medical Accelerator in Chiba (HIMAC) at National Institute of Radiological Sciences (NIRS) is reported. The beam intensity of the NIRS-ECR was increased by modifications on the magnetic field structure, chamber cooling system, vacuum conductance and the extraction configuration. The output current of Ar6+ reached 365 eμA after improvements. The good stability, easy operation, and good reproducibility were realized. (author)
Additional details
Publishing Information
- Imprint Title
- Proceedings of the 12th international workshop on ECR ion sources
- Imprint Pagination
- 363 p.
- Journal Page Range
- p. 259-263.
- Report number
- INS-J--182
Conference
- Title
- 12. international workshop on ECR ion sources; 24. INS symposium on ECR ion sources and their applications.
- Dates
- 25-27 Apr 1995.
- Place
- Wako, Saitama (Japan).
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 27051491
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BEAM CURRENTS; BEAM EXTRACTION; COOLING SYSTEMS; ELECTRON CYCLOTRON-RESONANCE; HEAVY IONS; HIMAC ACCELERATOR; ION SOURCES; MAGNETIC FIELD CONFIGURATIONS; OPERATION; RADIOTHERAPY; STABILITY; VACUUM SYSTEMS
- Descriptors DEC
- ACCELERATORS; CHARGED PARTICLES; CURRENTS; CYCLIC ACCELERATORS; CYCLOTRON RESONANCE; HEAVY ION ACCELERATORS; IONS; MEDICINE; RESONANCE; SYNCHROTRONS; THERAPY