Published 2020 | Version v1
Journal article

Improving the efficiency of the unit of the Zaporizhzhia NPP with a WWER–1000 reactor

  • 1. Zaporizhzhia National University, Zaporizhzhia (Ukraine)

Description

Improving the efficiency of the unit of the Zaporizhzhia NPP with a WWER–1000 reactor, by reducing the water temperature at the inlet to the condenser. The work describes the description of the NPP and the nuclear power reactor WWER–1000, by reducing the water temperature at the inlet to the condenser. Detailed neutron–physical calculation of the nuclear power unit with WWER–1000 reactor with a turbine installation K–1000 –60⁄3000. The influence of the temperature of cooling water on the input to the capacitor and the load on the efficiency of the turbine installation and the flow of steam and heat to the turbine installation is established. (author)

Additional details

Publishing Information

Journal Title
Voprosy Atomnoj Nauki i Tekhniki
Journal Issue
no.1-125
Journal Page Range
p. 135-139
ISSN
1562-6016