Published 2013 | Version v1
Miscellaneous Open

Dosimetric studies of the lens of the eye using a new dosimeter - polls in two departments of Interventional Radiology of the autonomous city of Buenos Aires

  • 1. Comisión Nacional de Energía Atómica, Av. Libertador 8250, C1429BNP CABA, Buenos Aires (Argentina)
  • 2. Sanatorio Dr. Julio Méndez, Avellaneda 551, C1405CNF CABA Buenos Aires (Argentina)

Description

During interventional radiology (IR) and cardiology (IC) procedures, medical staff can receive high doses to their eye lenses. The Retrospective Evaluation of Lens Injuries and Dose (RELID) study organized in Argentina in 2010 found incipient opacity in 50% of IC physicians and 41% of IC technicians/nurses. These results, added to the recommendations of the International Commission on Radiological Protection (ICRP), which lowered their former occupational equivalent dose limit for the lens, led us to assess the eye lens dose, Hp(3), during interventional procedures. To this end, a new dosemeter was designed and calibrated at the National Atomic Energy Commission (CNEA) of Argentina to evaluate Hp(3). Personal dose equivalent (Hp(10)), and Hp(3) were assessed for 3 months in two IC and IR departments of Buenos Aires City using thermoluminescent dosimeters (TLD) and electronic personal dosimeter (EPD). An Rando Alderson phantom was used to simulate monthly exposures of five occupational staff members. Hp(3) and Hp(10) were obtained monthly for 14 occupational staff members exposed to 121 IR and IC procedures. We concluded that the annual effective dose and Hp(3) were lower than 0.3 and 10 mSv, respectively. An occupational annual dose constraint of 0.3 mSv was calculated. Average cumulative Hp(3) for working life of 40 years should be lower than 400 and 200 mSv for physicians and technicians/scrub nurse, respectively. Also we concluded that a calibrated EPD worn on a pocket in the lead apron and a TLD dosemeter worn on the collar thyroid (both at the maximal radiation side) could be used as guidance to the lens dose. Finally, To reduce doses of medical staff, actions should be promoted to maximize radiation protection in interventional procedures with appropriate training, using personal dosimetry and protection instruments as lead glasses, ceiling-suspended shields and others. (author)

Files

46109490.pdf

Files (3.7 MB)

Name Size Download all
md5:f536dba54953f9d9cc77b393f086128d
3.7 MB Preview Download
Part of:
XL Annual meeting of the Argentine Association of Nuclear Technology (AATN 2013)

Additional details

Additional titles

Original title (Spanish)
Estudios dosimétricos del cristalino del ojo usando un nuevo dosímetro - encuestas en dos departamentos de radiología intervencionista de la Ciudad Autónoma de Buenos Aires

Publishing Information

Publisher
AATN
Imprint Place
Buenos Aires (Argentina)
Imprint Title
XL Annual meeting of the Argentine Association of Nuclear Technology (AATN 2013)
Imprint Pagination
[vp.]
Journal Page Range
17 p.
Report number
INIS-AR-C--1704

Conference

Title
40. Annual meeting of the Argentine Association of Nuclear Technology: Participation in the national nuclear energy landscape
Original Conference Title
AATN 2013: 40. Reunion anual de la Asociacion Argentina de Tecnologia Nuclear: Participacion nuclear en el panorama energetico nacional
Acronym
AATN 2013
Dates
9-13 Dec 2013
Place
Buenos Aires (Argentina)

Optional Information

Notes
32 refs., 5 figs., 2 tabs. Imprint:XL Reunion anual de la Asociacion Argentina de Tecnologia Nuclear (AATN 2013)