Published September 2006 | Version v1
Journal article

Investigation of tilted dose kernels for portal dose prediction in a-Si electronic portal imagers

  • 1. Department of Physics and Astronomy, University of Manitoba, Winnipeg, Manitoba R3T 2N2 (Canada) and Department of Radiology, University of Manitoba, Winnipeg, Manitoba R3A 1R9 (Canada)
  • 2. Division of Medical Physics, CancerCare Manitoba, 675 McDermot Avenue, Winnipeg, Manitoba R3E 0V9 (Canada)
  • 3. Division of Medical Physics, CancerCare Manitoba, 675 McDermot Avenue, Winnipeg, Manitoba R3E 0V9, Canada and Department of Physics and Astronomy, University of Manitoba, Winnipeg, Manitoba R3T 2N2 (Canada)

Description

The effect of beam divergence on dose calculation via Monte Carlo generated dose kernels was investigated in an amorphous silicon electronic portal imaging device (EPID). The flat-panel detector was simulated in EGSnrc with an additional 3.0 cm water buildup. The model included details of the detector's imaging cassette and the front cover upstream of it. To approximate the effect of the EPID's rear housing, a 2.1 cm air gap and 1.0 cm water slab were introduced into the simulation as equivalent backscatter material. Dose kernels were generated with an incident pencil beam of monoenergetic photons of energy 0.1, 2, 6, and 18 MeV. The orientation of the incident pencil beam was varied from 0 deg. to 14 deg. in 2 deg. increments. Dose was scored in the phosphor layer of the detector in both cylindrical (at 0 deg. ) and Cartesian (at 0 deg. -14 deg.) geometries. To reduce statistical fluctuations in the Cartesian geometry simulations at large radial distances from the incident pencil beam, the voxels were first averaged bilaterally about the pencil beam and then combined into concentric square rings of voxels. Profiles of the EPID dose kernels displayed increasing asymmetry with increasing angle and energy. A comparison of the superposition (tilted kernels) and convolution (parallel kernels) dose calculation methods via the χ-comparison test (a derivative of the γ-evaluation) in worst-case-scenario geometries demonstrated an agreement between the two methods within 0.0784 cm (one pixel width) distance-to-agreement and up to a 1.8% dose difference. More clinically typical field sizes and source-to-detector distances were also tested, yielding at most a 1.0% dose difference and the same distance-to-agreement. Therefore, the assumption of parallel dose kernels has less than a 1.8% dosimetric effect in extreme cases and less than a 1.0% dosimetric effect in most clinically relevant situations and should be suitable for most clinical dosimetric applications. The resulting time difference for the parallel kernel assumption versus the tilted kernels was 10.5 s vs 18 h (a factor of approximately 6000), dependent on existing hardware and software details

Additional details

Identifiers

Publishing Information

Journal Title
Medical Physics
Journal Volume
33
Journal Issue
9
Journal Page Range
p. 3333-3339
ISSN
0094-2405
CODEN
MPHYA6

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
38026443
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ACCIDENTS; BEAMS; COMPARATIVE EVALUATIONS; COMPUTER CODES; DOSIMETRY; IMAGES; KERNELS; MONTE CARLO METHOD; ORIENTATION; PHOTONS; RADIATION DOSES; RADIOTHERAPY; SILICON
Descriptors DEC
BOSONS; CALCULATION METHODS; DOSES; ELEMENTARY PARTICLES; ELEMENTS; EVALUATION; MASSLESS PARTICLES; MEDICINE; NUCLEAR MEDICINE; RADIOLOGY; SEMIMETALS; THERAPY

Optional Information

Notes
(c) 2006 American Association of Physicists in Medicine