Published November 2, 2010 | Version v1
Journal article

Radiation Exposure from CT Examinations in Japan

  • 1. Department of Diagnostic Radiology and Nuclear Medicine, Gunma University Hospital 3-39-22 Showa-machi, Maebashi, Gunma (Japan)

Description

Computed tomography (CT) is the largest source of medical radiation exposure to the general population, and is considered a potential source of increased cancer risk. The aim of this study was to assess the current situation of CT use in Japan, and to investigate variations in radiation exposure in CT studies among institutions and scanners. Data-sheets were sent to all 126 hospitals and randomly selected 14 (15%) of 94 clinics in Gunma prefecture which had CT scanner(s). Data for patients undergoing CT during a single month (June 2008) were obtained, along with CT scan protocols for each institution surveyed. Age and sex specific patterns of CT examination, the variation in radiation exposure from CT examinations, and factors which were responsible for the variation in radiation exposure were determined. An estimated 235.4 patients per 1,000 population undergo CT examinations each year, and 50% of the patients were scanned in two or more anatomical locations in one CT session. There was a large variation in effective dose among hospitals surveyed, particularly in lower abdominal CT (range, 2.6-19.0 mSv). CT examinations of the chest and upper abdomen contributed to approximately 73.2% of the collective dose from all CT examinations. It was estimated that in Japan, approximately 29.9 million patients undergo CT annually, and the estimated annual collective effective dose in Japan was 277.4 *103 Sv person. The annual effective dose per capita for Japan was estimated to be 2.20 mSv. There was a very large variation in radiation exposure from CT among institutions surveyed. CT examinations of the chest and upper abdomen were the predominant contributors to the collective dose

Availability note (English)

Available from http://dx.doi.org/10.1186/1471-2342-10-24; Available from http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2984464

Additional details

Publishing Information

Journal Title
BMC medical imaging (Online)
Journal Volume
10
Journal Page Range
p. 24
ISSN
1471-2342

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
46092441
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY; S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ABDOMEN; CHEST; DOSES; HAZARDS; HOSPITALS; JAPAN; NEOPLASMS; PATIENTS; POPULATIONS; SEX; SHEETS
Descriptors DEC
ASIA; BODY; BUILDINGS; DEVELOPED COUNTRIES; DISEASES; MEDICAL ESTABLISHMENTS

Optional Information

Copyright
Copyright (c)2010 Tsushima et al
Notes
PMCID: PMC2984464; PUBLISHER-ID: 1471-2342-10-24; PMID: 21044293; OAI: oai:pubmedcentral.nih.gov:2984464; licensee BioMed Central Ltd.