Published February 1995 | Version v1
Journal article

Experimental study on flow rate measurement of buoyancy-driven exchange flow

  • 1. Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan)

Description

An experimental investigation was carried out for the buoyancy-driven exchange flow in a narrow vertical pipe concerning the air ingress process during a stand-pipe rupture in a high-temperature gas-cooled reactor. In the current study, the evaluation method of exchange flow was developed by measuring the velocity in the pipe using a laser Doppler velocimeter. The experiments were performed under atmospheric pressure with nitrogen as a working fluid. The Rayleigh numbers range from 2.0 x 104 to 2.1 x 105. The exchange flow fluctuated irregularly with time and space in the pipe. It was found that the exchange-velocity distribution along the horizontal axis changed from one- to two-humped curves with increasing Rayleigh number. In the case that the lower plenum wall was cooler than the heated disk, the volumetric exchange flow rate was smaller than that in the case where the lower plenum wall and heated disk were kept at the same temperature

Additional details

Publishing Information

Journal Title
Nuclear Technology
Journal Volume
109
Journal Issue
2
Journal Page Range
p. 236-245.
ISSN
0029-5450
CODEN
NUTYBB

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
27015630
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Numerical Data
Descriptors DEI
DESIGN BASIS ACCIDENTS; EXPERIMENTAL DATA; GAS FLOW; HTGR TYPE REACTORS; MASS TRANSFER; REACTOR SAFETY EXPERIMENTS; SAFETY ANALYSIS; TIME DEPENDENCE
Descriptors DEC
ACCIDENTS; DATA; FLUID FLOW; GAS COOLED REACTORS; GRAPHITE MODERATED REACTORS; INFORMATION; NUMERICAL DATA; REACTOR ACCIDENTS; REACTORS