The neutron magnetic moment μ/sub n/ has been measured with an improvement of 2 orders of magnitude in experimental accuracy. The separated-oscillatory-field magnetic resonance technique was employed using slow neutrons and protons (in flowing water) in the same magnetic field. We find the ratio of neutron to proton moment to be μ/sub n//μ/sub p/ = -0.684 979 35(17) (0.25 ppm). Expressed in Bohr magnetons μ/sub B/ this gives μ/sub n//μ/sub B/ = -1.041 875 64(26) x 10-3. Expressed in nuclear magnetons μ/sub N/, μ/sub n//μ/sub N/ = -1.913 041 84
Additional details
Publishing Information
- Journal Title
- Phys. Rev., D
- Journal Volume
- 20
- Journal Issue
- 9
- Series
- Phys. Rev., D.
- Journal Page Range
- 2139-2153
- ISSN
- 0556-2821
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 11515995
- Subject category
- S72: PHYSICS OF ELEMENTARY PARTICLES AND FIELDS;
- Descriptors DEI
- DEUTERONS; DIRAC EQUATION; MAGNETIC FIELDS; MAGNETIC MOMENTS; MAGNETIC RESONANCE; NEUTRONS; PROTONS; QUADRUPOLE MOMENTS
- Descriptors DEC
- BARYONS; CATIONS; CHARGED PARTICLES; DIFFERENTIAL EQUATIONS; ELEMENTARY PARTICLES; EQUATIONS; FERMIONS; FIELD EQUATIONS; HADRONS; HYDROGEN IONS; HYDROGEN IONS 1 PLUS; IONS; NUCLEONS; RESONANCE