Published November 2018 | Version v1
Journal article

Numerical investigation of a novel vacuum photovoltaic curtain wall and integrated optimization of photovoltaic envelope systems

  • 1. Renewable Energy Research Group (RERG), Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong (China)

Description

Highlights: • VPV IGU can reduce up to 81.63% and 75.03% of heat gain in Hong Kong and Harbin. • Sensitivity analysis is conducted to evaluate the influence of design parameters. • High-efficiency design optimization is suitable and reliable for initial designs. • VPV IGU is more suitable for application in cold areas with small glazing area. • Systematic approach detailed can provide user guidelines for BIPV applications. This study presents a comprehensive investigation of the thermal and power performance of a novel vacuum photovoltaic insulated glass unit (VPV IGU) as well as an integrated design optimization of photovoltaic envelope systems. A prototype office building model with a curtain wall design is first constructed in EnergyPlus to compare the heat gain, heat loss, thermal load, lighting energy and PV generation for different curtain walls. The comparative analysis proves the excellent thermal insulating performance of VPV IGU, which can reduce up to 81.63% and 75.03% of the heat gain as well as 31.94% and 32.03% of the heat loss in Hong Kong (HK) and Harbin (HB) respectively. With the application of VPV IGU in all available facades of the prototype building, net energy savings of 37.79% and 39.82% can be achieved in diverse climatic conditions. Furthermore, screening and variance based sensitivity analyses are conducted to prioritize building integrated photovoltaic design parameters with respect to specific weather conditions. The selected important design parameters are then optimized with the non-dominated sorting genetic algorithm-II (NSGA-II), by which the optimum building design can achieve a net energy consumption reduction of 48.72% and 60.80% compared to benchmarking designs in Hong Kong and Harbin. Such an integrated design optimization can successfully improve computation efficiency with an acceptable solution accuracy, and assist the incorporation of PV envelop systems with passive architectural designs. The novel VPV IGU is determined to be more suitable for cold areas where the curtain wall design should also be avoided for energy conservation.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.apenergy.2018.08.095

Additional details

Identifiers

DOI
10.1016/j.apenergy.2018.08.095;
PII
S0306261918312662;

Publishing Information

Journal Title
Applied Energy
Journal Volume
229
Journal Page Range
p. 1048-1060
ISSN
0306-2619
CODEN
APENDX

Optional Information

Copyright
Copyright (c) 2018 Elsevier Ltd. All rights reserved.