NINO: an ultra-fast and low-power front-end amplifier/discriminator ASIC designed for the multigap resistive plate chamber
Creators
- 1. EP Division, CERN, Geneva (Switzerland)
- 2. Institute for Theoretical and Experimental Physics, Moscow (Russian Federation)
- 3. Institute for High Energy Physics, Protvino (Russian Federation)
- 4. Sezione INFN, Bologna (Italy)
- 5. Dipartimento di Fisica dell'Universita, Bologna (Italy)
Description
For the full exploitation of the excellent timing properties of the Multigap Resistive Plate Chamber (MRPC), front-end electronics with special characteristics are needed. These are (a) differential input, to profit from the differential signal from the MRPC (b) a fast amplifier with less than 1ns peaking time and (c) input charge measurement by Time-Over-Threshold for slewing correction. An 8-channel amplifier and discriminator chip has been developed to match these requirements. This is the NINO ASIC, fabricated with 0.25μm CMOS technology. The power requirement at 40mW/channel is low. Results on the performance of the MRPCs using the NINO ASIC are presented. Typical time resolution σ of the MRPC system is in the 50ps range, with an efficiency of 99.9%
Additional details
Identifiers
- DOI
- 10.1016/j.nima.2004.07.024;
- PII
- S0168-9002(04)01429-9;
Publishing Information
- Journal Title
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Journal Volume
- 533
- Journal Issue
- 1-2
- Journal Page Range
- p. 183-187
- ISSN
- 0168-9002
- CODEN
- NIMAER
Conference
- Title
- 7. international workshop on resistive plate chambers and related detectors
- Dates
- 20-22 Oct 2003
- Place
- Clermont-Ferrand (France)
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 37026735
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ALICE; AMPLIFIERS; CORRECTIONS; CURIUM OXIDES; EFFICIENCY; PERFORMANCE; PLATES; SIGNALS; TIME RESOLUTION; TIME-OF-FLIGHT METHOD
- Descriptors DEC
- ACTINIDE COMPOUNDS; CHALCOGENIDES; CURIUM COMPOUNDS; ELECTRONIC EQUIPMENT; EQUIPMENT; MAGNETIC MIRRORS; OPEN PLASMA DEVICES; OXIDES; OXYGEN COMPOUNDS; RESOLUTION; THERMONUCLEAR DEVICES; TIMING PROPERTIES; TRANSPLUTONIUM COMPOUNDS; TRANSURANIUM COMPOUNDS
Optional Information
- Copyright
- Copyright (c) 2004 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.