The thickness of Cu filter to reduce 1/2 of the patient dose
Creators
- 1. College of Health Sciences, Korea Univ., Seoul (Korea, Republic of)
- 2. Gachun Gil College, Incheon (Korea, Republic of)
Description
Medical X-ray examination are increased double for the last 6 ∼ 8 years. Therefore a patient exposure dose should be decrease half every 7 years. We made an experiment on copper filter thickness to decrease a patient exposure dose up to half and compared to the image quality by MTF. The results as follow a thin region like extremities needs a thicker Cu filter as compared a thick region. 1/2 reduction filter must be thicker when kVp increase. Exposure factor should be increas when using 1/2 reduction filter : extremity is 4.0 times, chest 2.9 times, skull 1.62 times, and abdomen 1.58 times. The MTF of using 1/2 reduction filter is lower than without filter. But no difference of visual image. 1/2 reduction filter compared with double speed screen showed almost same image quality
Additional details
Publishing Information
- Journal Title
- Journal of the Korean Society of Radiological Technology
- Journal Volume
- 24
- Journal Issue
- 1
- Series
- 8 refs, 9 figs, 4 tabs
- Journal Page Range
- p. 17-22
- ISSN
- 1226-2854
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 32067181
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- COPPER; FILTERS; IMAGES; MEDICAL EXAMINATIONS; PATIENTS; RADIATION DOSES; X-RAY RADIOGRAPHY
- Descriptors DEC
- DOSES; ELEMENTS; INDUSTRIAL RADIOGRAPHY; MATERIALS TESTING; MEDICAL SURVEILLANCE; METALS; NONDESTRUCTIVE TESTING; TESTING; TRANSITION ELEMENTS