Published 1995
| Version v1
Journal article
Relaxation of rod misalignment technical specification requirements: An increased operational flexibility
Creators
- 1. American Electric Power Services Corporation, Columbus, OH (United States)
- 2. Westinghouse Electric Corporation, Pittsburgh, PA (United States)
Description
The pressurized water reactor technical specification (T/S) limiting condition for operation (LCO) for rod misalignment and rod position indication (RPI) typically requires all rod cluster control assemblies to be positioned with ±12 steps of the group demand position. The LCO is approved by the U.S. Nuclear Regulatory Commission (NRC) for use by all Westinghouse plants, and the core design incorporates a peaking factor uncertainty to accommodate potential rod misalignments within this approved LCO. Also, the LCO requires all RPI channels and the demand position indicator system to be operable and capable of determining the control rod position within ±12 steps
Additional details
Publishing Information
- Journal Title
- Transactions of the American Nuclear Society
- Journal Volume
- 73
- Journal Page Range
- p. 237-239.
- ISSN
- 0003-018X
- CODEN
- TANSAO
Conference
- Title
- Winter meeting of the American Nuclear Society (ANS).
- Dates
- 29 Oct - 1 Nov 1995.
- Place
- San Francisco, CA (United States).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 28018960
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CALCULATION METHODS; CONTROL ELEMENTS; INSTABILITY; PWR TYPE REACTORS; REACTOR SAFETY
- Descriptors DEC
- ENRICHED URANIUM REACTORS; POWER REACTORS; REACTOR COMPONENTS; REACTORS; SAFETY; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Secondary number(s)
- CONF-951006--.