Published January 1995 | Version v1
Journal article

Scintillating-fiber 14 MeV neutron detector on TFTR during DT operation

  • 1. Los Alamos National Laboratory, Los Alamos, New Mexico 87544 (United States)
  • 2. Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States)
  • 3. EG ampersand G Energy Measurements, Las Vegas, Nevada 89125 (United States)

Description

A compact 14 MeV neutron detector using an array of scintillating fibers has been tested on the TFTR tokamak under conditions of a high gamma background. This detector uses a fiber-matrix geometry, a magnetic field-insensitive phototube with an active HV base and pulse-height discrimination to reject low-level pulses from 2.5 MeV neutrons and intense gammas. Laboratory calibrations have been performed at EG ampersand G Las Vegas using a pulsed DT neutron generator and a 30 kCi 60Co source as background, at PPPL using DT neutron sources, and at LANL using an energetic deuterium beam and target at a tandem Van de Graaff accelerator. During the first high-power DT shots on TFTR in December 1993, the detector was 15.5 m from the torus in a large collimator. For a rate of 1x1018 n/s from the tokamak, it operated in an equivalent background of 1x1010 gammas/cm2/s (∼4 mA current drain) at a DT count rate of 200 kHz

Additional details

Publishing Information

Journal Title
Review of Scientific Instruments
Journal Volume
66
Journal Issue
1
Journal Page Range
p. 901-903.
ISSN
0034-6748
CODEN
RSINAK