Published March 1983
| Version v1
Journal article
The measurement of photodissociation rate in the optically pumped iodine laser
Creators
- 1. Busan Sanup Univ. (Republic of Korea)
- 2. Kyungpook National Univ., Taegu (Republic of Korea)
Description
In this experiment we have measured the photodissociation rate i-Csub(3)Fsub(7)I used in iodine photodissociation laser. To measure the photodissociation rate, we have used the threshold condition of laser oscillation. Using various neutral density filters with different optical density and three different output mirrors with various reflectances, we have 15% of photodissociation in i-Csub(3)Fsub(7)I at the pressure of 60 torr in the laser tube. (Author)
Additional details
Publishing Information
- Journal Title
- Univ. J., Busan Sanup Univ.
- Journal Volume
- 4
- Series
- Univ. J., Busan Sanup Univ.
- Journal Page Range
- 55-59
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 15019650
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- IODINE; LASERS; OPTICAL PUMPING; PHOTONUCLEAR REACTIONS
- Descriptors DEC
- AMPLIFIERS; ELEMENTS; EQUIPMENT; HALOGENS; NONMETALS; NUCLEAR REACTIONS