Published August 17, 1995 | Version v1
Report Open

Removing gaseous contaminants in 3He by cryogenic stripping

  • 1. Lawrence Livermore National Lab., CA (United States). Tritium Operations Group

Description

The Tritium Operations Group at LLNL, Tritium Facility has recently developed a 3He recovery system to remove argon, xenon, neon, hydrogen, and all other contaminants from the 3He stream in an Accelerator Production of Tritium (APT) experimental apparatus. In this paper the authors will describe in detail the background information, technical requirements, the design approach, and the results of their experimental tests. The authors believe this gas purification system may have other applications as it provides at a reasonable cost an efficient method for purification of gaseous helium

Availability note (English)

MF available from INIS under the Report Number; Also available from OSTI as DE96004596; NTIS; US Govt. Printing Office Dep.

Files

27041486.pdf

Files (682.6 kB)

Name Size Download all
md5:a3577145dc6aff2a8dc66308b3fa99b1
682.6 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
18 p.
Report number
UCRL-JC--122233

Conference

Title
8. annual meeting of the Interagency Mechanical Operations Group Gas Technology Subgroup.
Dates
24-26 Oct 1995.
Place
Aiken, SC (United States).

Optional Information

Contract/Grant/Project number
Contract W-7405-ENG-48
Funding organization
USDOE, Washington, DC (United States).
Secondary number(s)
CONF-9510277--1.