A study of the multigap RPC at the gamma irradiation facility at CERN

Description

The selected device for the ALICE Time-of-Flight array is the Multigap Resistive Plate Chamber (MRPC). We have tested this device at the Gamma Irradiation Facility at CERN to evaluate the rate dependence. We find that the rate capability of the MRPC easily exceeds the 50 Hz/cm2 maximum expected rate at the ALICE experiment. In addition, we have measured the power dissipated for an equivalent flux of 1.6 kHz/cm2 of through-going muons to be 650 mW/m2

Additional details

Identifiers

PII
S016890020200918X;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
490
Journal Issue
1-2
Journal Page Range
p. 58-70