Published September 1996 | Version v1
Journal article

Application of ICP-MS for the assessment of thorium excretion in urine

  • 1. GSF - Forschungszentrum fuer Umwelt und Gesundheit Neuherberg GmbH, Oberschleissheim (Germany). Inst. fuer Strahlenschutz
  • 2. GSF - Forschungszentrum fuer Umwelt und Gesundheit GmbH, Neuherberg (Germany). Inst. fuer Oekologische Chemie

Description

A method for rapid and sensitive determination of thorium in urine by inductively coupled plasma mass spectrometry (ICP-MS) is described. The method is sufficiently sensitive to detect 1 ng/L 232Th in urine without any sample preparation. The mean urinary 232Th excretion in 23 unexposed subjects was 6.2 ± 3.3 ng/d. (author)

Additional details

Publishing Information

Journal Title
Applied Radiation and Isotopes
Journal Volume
47
Journal Issue
9-10
Journal Page Range
p. 1055-1056.
ISSN
0969-8043
CODEN
ARISEF

Conference

Title
International Committee for Radionuclide Metrology conference on low-level measurement techniques.
Dates
2-6 Oct 1995.
Place