Computed tomography (CT) has become a major source of the population exposure to diagnostic X-rays, and acknowledge of the doses delivered by the CT equipment has become very important. Considerable efforts should be made to keep these doses to a reasonable minimum, without sacrificing the image quality. The conditions of exposure in CT are quite different from dose in conventional X-ray imaging. This has required the development of specific techniques for assessing patient dose from CT. The aims of this work were to determine the dose delivered to various organs of patients undergoing computed tomography of abdomen as measured on the surface of the body and to estimate the risk to the patients. Dosimetric measurements were performed at CT scanner Hitachi W 450 in General Hospital Karlovac. The doses absorbed by different organs (gonads, chest, thyroid and eye lens) and by the examined part of the body of 11 patients were measured with TLD-700. The doses absorbed by different organs during the diagnostic CT examination of the body depend on the technical parameters, such as the number of scans, mAs, the thickness of scans, scanning times, tube voltage and other characteristics. The type and severity of illness influence the choice of technical parameters. Clinical parameters, such as patient size and composition, and patient cooperation with regard to the control and motion, also influence the dose and the image quality. The highest dose measured in this study (112.5 mGy) was delivered to front surface of the body during CT examination of abdomen. (author)

Files

30017664.pdf

Files (120.5 kB)

Name Size Download all
md5:a204d7640488f2dc17db04c7dfe74d45
120.5 kB Preview Download
Part of:
Proceedings of the Fourth Symposium of the Croatian Radiation Protection Association

Additional details

Additional titles

Original title (Croatian)
Povrsinske doze pacijenata pri CT pretragama abdomena u Opcoj bolnici Karlovac

Publishing Information

Imprint Place
Zagreb (Croatia)
ISBN
953-96133-2-9
Imprint Title
Proceedings of the Fourth Symposium of the Croatian Radiation Protection Association
Imprint Pagination
369 p.
Journal Page Range
p. 315-320
Report number
INIS-HR--99001

Conference

Title
4. Symposium of the Croatian Radiation Protection Association
Original Conference Title
Cetvrti simpozij Hrvatskog drustva za zastitu od zracenja
Dates
11-13 Nov 1998
Place
Zagreb (Croatia)

INIS

Country of Publication
Croatia
Country of Input or Organization
Croatia
INIS RN
30017664
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE; S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CAT SCANNING; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC USES; PATIENTS; RADIATION DOSES; RADIATION MONITORING; RADIATION PROTECTION
Descriptors DEC
ANIMALS; COMPUTERIZED TOMOGRAPHY; MAMMALS; MAN; MONITORING; PRIMATES; TOMOGRAPHY; USES; VERTEBRATES

Optional Information

Notes
11 refs., 1 tab. Imprint:Zbornik radova Cetvrtog simpozija Hrvatskog drustva za zastitu od zracenja