Published October 1984 | Version v1
Report

Inspection of a condenser in Oskarshamn 2

Creators

  • 1. Korrosionsinstitutet

Description

The condenser, which has titanium tubes roller-expanded in tube plates of clad steel (type 316), revealed no corrosion attack requiring protective measures apart from those already adopted - sacrificial anodes of soft iron during operation and continuous freshwater rinsing of the tube plates during shutdown. The surfaces of the tube plates which were experimentally coated with min 500 μm solvent-free epoxy coating were in very good condition. (author)

Additional details

Additional titles

Original title (Swedish)
Inspektion av en kondensor i Oskarshamn 2

Publishing Information

Imprint Title
Sea water corrosion - follow up an advisory service, July 1983-July 1984
Imprint Pagination
22 p.
Journal Page Range
p. 2.
Report number
SVF--168

Optional Information

Notes
Imprint:Havsvattenkorrosion, Praktikfall juli 1983-juli 1984.