Published March 20, 2003 | Version v1
Report

Technical basis for the aboveground structure failure and associated represented hazardous conditions

Description

The purpose of the Technical Basis Document is to determine the consequences and FR-equency of aboveground structure failures. These failures include drops of contained equipment, such as a pump, FR-om a SST or DST, a crane failure resulting in a load drop onto a HEPA filter. These failures can result in an uncontrolled release of radiological and toxicological material

Availability note (English)

Available FR-om PURL: https://www.osti.gov/servlets/purl/810642-lo2Btt/native/

Additional details

Publishing Information

Imprint Pagination
45 p.
Report number
RPP--14618

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
34043748
Subject category
S11: NUCLEAR FUEL CYCLE AND FUEL MATERIALS;
Resource subtype / Literary indicator
Non-conventional Literature
Descriptors DEI
FAILURES; MECHANICAL STRUCTURES; RADIATION ACCIDENTS; RISK ASSESSMENT
Descriptors DEC
ACCIDENTS