Initial evaluation of a commercial EPID modified to a novel direct-detection configuration for radiotherapy dosimetry

  • 1. Institute of Medical Physics, School of Physics, University of Sydney, Sydney 2006 (Australia)
  • 2. Royal North Shore Hospital, Sydney 2065 (Australia) and Institute of Medical Physics, School of Physics, University of Sydney, Sydney 2006 (Australia)
  • 3. Calvary Mater Newcastle Hospital, Newcastle 2298, Australia and University of Newcastle, Newcastle 2308 (Australia)
  • 4. Department of Medical Physics, Liverpool and Macarthur Cancer Therapy Centres, Sydney 2170, Australia and Institute of Medical Physics, School of Physics, University of Sydney, Sydney 2006 (Australia)

Description

Electronic portal imaging devices (EPIDs) integrated with medical linear accelerators utilize an indirect-detection EPID configuration (ID-EPID). Amorphous silicon ID-EPIDs provide high quality low dose images for verification of radiotherapy treatments but they have limitations as dosimeters. The standard ID-EPID configuration includes a high atomic number phosphor scintillator screen, a 1 mm copper layer, and other nonwater equivalent materials covering the detector. This configuration leads to marked differences in the response of an ID-EPID compared to standard radiotherapy dosimeters such as ion chambers in water. In this study the phosphor and copper were removed from a standard commercial EPID to modify the configuration to a direct-detection EPID (DD-EPID). Using solid water as the buildup and backscatter for the detector, dosimetric measurements were performed on the DD-EPID and compared to standard dose-in-water data for 6 and 18 MV photons. The sensitivity of the DD-EPID was approximately eight times less than the ID-EPID but the signal was sufficient to produce accurate and reproducible beam profile measurements for open beams and an intensity-modulated beam. Due to the lower signal levels it was found necessary to ensure that the dark field correction (no radiation) DD-EPID signal was stable or updated frequently. The linearity of dose response was comparable to the ID-EPID but with a greater under-response at low doses. DD-EPID measurements of field size output factors and beam profiles at the depth of maximum dose (dmax), and tissue-maximum ratios between the depths of 0.5 and 10 cm, were in close agreement with dose in water measurements. At depths beyond dmax the DD-EPID showed a greater change in response to field size than ionisation chamber measurements and the beam penumbrae were broader compared to diode scans. The modified DD-EPID configuration studied here has the potential to improve the performance of EPIDs for dose verification of radiotherapy treatments.

Additional details

Identifiers

Publishing Information

Journal Title
Medical Physics
Journal Volume
35
Journal Issue
10
Journal Page Range
p. 4362-4374
ISSN
0094-2405
CODEN
MPHYA6

Optional Information

Notes
(c) 2008 American Association of Physicists in Medicine