Published November 11, 2005 | Version v1
Journal article

CLAM, a continuous line alignment and monitoring method for RICH mirrors

  • 1. INFN Sezione di Torino and University of Torino, Turin (Italy)
  • 2. INFN Sezione di Trieste, Trieste (Italy)
  • 3. CERN, European Organization for Nuclear Research, Geneva (Switzerland)

Description

A method is proposed for the angular alignment of RICH mirrors and for its monitoring, in particular for the COMPASS RICH-1 mirror system. Observing (by means of four cameras) apparent discontinuities in the images of continuous linear objects reflected by the mirrors surface, a relative misalignment of adjacent mirrors can be deduced and then corrected. The method can attain a sensitivity of at least 0.1 mrad, and can also be applied on-line to keep under control the stability of the mirrors during data taking

Additional details

Identifiers

DOI
10.1016/j.nima.2005.08.034;
PII
S0168-9002(05)01586-X;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
553
Journal Issue
1-2
Journal Page Range
p. 135-139
ISSN
0168-9002
CODEN
NIMAER

Conference

Title
5. international workshop on ring imaging detectors
Dates
30 Nov - 5 Dec 2004
Place
Playa de Carmen, Yucatan Peninsula (Mexico)

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
37072730
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ALIGNMENT; CAMERAS; COMPASS-D TOKAMAK; CONTROL; IMAGES; MIRRORS; MONITORING; SENSITIVITY; STABILITY; SURFACES
Descriptors DEC
CLOSED PLASMA DEVICES; THERMONUCLEAR DEVICES; TOKAMAK DEVICES