Published September 2008 | Version v1
Journal article

Lung 4D-IMRT treatment planning: An evaluation of three methods applied to four-dimensional data sets

  • 1. Department of Medical Physics, University of Wisconsin - Madison, WI (United States)
  • 2. Department of Human Oncology, University of Wisconsin - Madison, WI (United States)

Description

Purpose: To compare 4D-dose distributions for IMRT planning on three data sets: a single 4D-CT phase, a 4D-CT phase with a density override to the tumor motion envelope (TME) volume, and the average intensity projection (AIP). Methods: Eight planning cases were considered. IMRT inverse planning optimization was performed on each of the three data set types, for each case considered. The plans were then applied to all ten phases of the associated 4D-CT data set. The dose to the GTV in each breathing phase was compared to the TME dose from the optimized dose distribution, as well as the GTV dose determined from a model-based deformable registration algorithm. Results: IMRT optimization on a single 3D data set resulted in a greater equivalent uniform dose (EUD) to the GTV when applied to a 4D-CT data set than the EUD for the TME in the optimized plan. The difference was up to 5.5 Gy in one case. For all cases and planning techniques considered, a maximum difference of 0.3 Gy in the NTDmean to the healthy lung throughout the breathing cycle was found. Conclusions: For tumors located in the periphery of the lung, optimization on the AIP image resulted in a more uniform GTV dose throughout the breathing cycle. Averages in GTV EUD and healthy lung NTDmean taken over all the breathing phases were found to be in agreement with the dose effect parameters obtained from model-based deformable registration algorithms. All planning methods yielded GTV EUD values that were larger than the prescribed dose when the full 4D data set was considered

Availability note (English)

Available from http://dx.doi.org/10.1016/j.radonc.2008.07.004

Additional details

Identifiers

DOI
10.1016/j.radonc.2008.07.004;
PII
S0167-8140(08)00368-X;

Publishing Information

Journal Title
Radiotherapy and Oncology
Journal Volume
88
Journal Issue
3
Journal Page Range
p. 319-325
ISSN
0167-8140
CODEN
RAONDT

INIS

Country of Publication
Ireland
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
40005316
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ALGORITHMS; COMPUTERIZED TOMOGRAPHY; IMAGE PROCESSING; IMAGES; LUNGS; NEOPLASMS; OPTIMIZATION; PLANNING; RADIATION DOSE DISTRIBUTIONS; RADIATION DOSES; RESPIRATION
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; DISEASES; DOSES; MATHEMATICAL LOGIC; ORGANS; PROCESSING; RESPIRATORY SYSTEM; TOMOGRAPHY

Optional Information

Copyright