Published 1991
| Version v1
Report
Open
The pions and electrons identification in the modular hadron sampling-calorimeter
Creators
- 1. Joint Inst. for Nuclear Research, Dubna (Russian Federation). Lab. of High Energy
- 2. Gosudarstvennyj Komitet po Ispol'zovaniyu Atomnoj Ehnergii SSSR,
Description
The possibility of hadrons and electrons rejection in hadron sampling-calorimeter with shower profile distribution has been investigated. The dependence of shower profile dispersion and profile form on shower axis position, cell sizes, sort and energy of particles have been studied. The introduction of limitation for shower width allowed one to supress the electron registration to the level about 10-2 with π- -meson registration effectivity about 90%. The same level is achieved with hadron supression and identification of electrons. 13 refs.; 8 figs
Availability note (English)
MF available from INIS under the Report Number.Files
24019689.pdf
Files
(301.6 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:d2d8a05ff122d7bc520ea483e7ebe7c5
|
301.6 kB | Preview Download |
System files
(30.4 kB)
| Name | Size | Download all |
|---|
Additional details
Additional titles
- Original title (Russian)
- Идентификация пионов и электронов в адронном сэмплинг -калориметре ячеистого типа
Publishing Information
- Imprint Pagination
- 10 p.
- Report number
- JINR-R--1-91-554
INIS
- Country of Publication
- Russian Federation
- Country of Input or Organization
- Russian Federation
- INIS RN
- 24019689
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- ANALYTICAL SOLUTION; ELECTRONS; ENERGY LOSSES; HADRONS; PARTICLE IDENTIFICATION; PIONS MINUS; SAMPLING; SHOWER COUNTERS; SPECTROMETERS
- Descriptors DEC
- BOSONS; ELEMENTARY PARTICLES; FERMIONS; LEPTONS; MEASURING INSTRUMENTS; MESONS; PIONS; PSEUDOSCALAR MESONS; RADIATION DETECTORS
Optional Information
- Notes
- Submitted to Prib. Tekh. Ehksp.