Published 1992
| Version v1
Report
Restricted
Effect of dead materials on calorimeter response and Monte Carlo simulation
Creators
- 1. Florida State Univ., Tallahassee, FL (United States). Dept. of Physics
Description
The D0 calorimeter system, cylindrical central calorimeter and two end calorimeters, is constructed with minimal cracks and dead regions in order to provide essentially hermetic coverage over the full solid angle. The effect of the existing few construction features which could perturb the uniformity of the calorimeter is studied in detail with beam tests. The results with the correction algorithms are presented. A comparison with the Monte Carlo simulation is made
Availability note (English)
MF available from INIS under the Report Number; OSTI as DE93004748; NTIS; INIS; US Govt. Printing Office Dep.
Files
Additional details
Publishing Information
- Imprint Pagination
- 10 p.
- Report number
- FNAL/C--92/309
Conference
- Title
- 3. international conference on calorimetry in high energy physics.
- Dates
- 29 Sep - 20 Oct 1992.
- Place
- Corpus Christi, TX (United States).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 24039138
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CRACKS; EVALUATION; FERMILAB TEVATRON; MONTE CARLO METHOD; SHOWER COUNTERS
- Descriptors DEC
- ACCELERATORS; CALCULATION METHODS; CYCLIC ACCELERATORS; MEASURING INSTRUMENTS; RADIATION DETECTORS; SYNCHROTRONS
Optional Information
- Contract/Grant/Project number
- Contract AC02-76CH03000
- Collaborations
- D0 Collaboration.
- Funding organization
- USDOE, Washington, DC (United States); National Science Foundation, Washington, DC (United States).
- Secondary number(s)
- CONF-9210262--1.