Published August 2001 | Version v1
Report Open

Calculating model of testing power of the HFETR 4 x 4 - fuel assembly

  • 1. Nuclear Power Inst. of China, Chengdu (China)

Description

A calculating model for maximum allowable power of 4 x 4 - 4 fuel assembly is established. The power conducted from inside the square duct to the water outside is calculated. A evaluation model is also established for heat releasing of γ ray from HFETR fuel elements in 4 x 4 - 4 fuel assembly. The calculation result of maximum allowable power of the assembly is presented

Availability note (English)

Available from INIS in electronic form

Files

33019168.pdf

Files (378.6 kB)

Name Size Download all
md5:0132bb7e0667457c1c3e276840cf9445
378.6 kB Preview Download

Additional details

Publishing Information

ISBN
7-89999-840-9
Imprint Pagination
8 p.
Journal Issue
CNIC/CD/2001-2
Series
China Nuclear Science and Technology Report
Report number
CNIC--01558

Optional Information

Notes
Data in PDF format: Acrobat Reader for Windows 9x
Secondary number(s)
SINRE--0094