Published August 2014 | Version v1
Miscellaneous Open

Quantification of the reproducibility of the positioning in patients that receive radiotherapy with immobilization devices for treatments with VMAT using DRR and CBCT

  • 1. ALIADA, Oncologia Integral, Av. Jose Galvez Barrenechea 1044, San Isidro, Lima 27 (Peru)

Description

The technological advances and the introduction of digital and computer systems to the treatment equipment s have contributed significantly in the precision when is necessary to deliver and distributing radiation dose in the planning volume where is located the tumor, besides also considering the healthy organs and tissues or in risk. For this treatment modality is necessary take into account the great importance that has the positioning, and immobilization and its reproducibility, making use of appropriate and personalized accessories that guarantee the bigger possible precision when the images are compared of before and after the treatment. For this study positioning data of 34 patients were quantified, which were treated with Volumetric Modulated Arc Therapy (VMAT) for the period between May to November of 2013. Of the patients 16 were treated in head and neck and 18 of prostate and abdomen. In all cases of head and neck treatment with VMAT immobilizer meshes were used that hold until the patient's neck, and in the cases of prostate and abdomen was used an immobilizer device under the knees and the ankles. All the cases were re-positioning using positioning techniques with Digitally Reconstructed Radiograph images (DRR) with acquisition modality Kv/Kv and Cone Beam the corrections and monitoring were carried out daily. Variations existed during the treatments that oscillate of 1-2 mm in the head and neck cases; and 2-4 mm in prostate and abdomen, these variations are necessary to quantify them in pro of the reproducibility in the patients positioning that receive radiotherapy and use immobilization device. (Author)

Files

46021479.pdf

Files (323.6 kB)

Name Size Download all
md5:2f98f0d1926870988b1a4fe91bbff909
323.6 kB Preview Download

Additional details

Additional titles

Original title (Spanish)
Cuantificacion de la reproducibilidad del posicionamiento en pacientes que reciben radioterapia con dispositivos de inmovilizacion para tratamientos con VMAT utilizando DRR y CBCT

Publishing Information

Publisher
Sociedad Mexicana de Irradiacion y Dosimetria
Imprint Place
Mexico, D. F. (Mexico)
Imprint Pagination
9 p.
Report number
INIS-MX--2829

Conference

Title
14. International Symposium on Solid State Dosimetry
Original Conference Title
14. Conferencia Internacional sobre Dosimetria de Estado Solido
Dates
13-16 Apr 2014
Place
Cusco (Peru)

INIS

Country of Publication
Mexico
Country of Input or Organization
Mexico
INIS RN
46021479
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ABDOMEN; ACCURACY; ANIMAL TISSUES; BEAMS; BONE JOINTS; COMPARATIVE EVALUATIONS; CONES; CORRECTIONS; DIGITAL SYSTEMS; EQUIPMENT; HEAD; IMAGES; MONITORING; NECK; NEOPLASMS; PATIENTS; PLANNING; PROSTATE; RADIATION DOSES; RADIOTHERAPY
Descriptors DEC
BODY; DISEASES; DOSES; EVALUATION; GLANDS; MALE GENITALS; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; SKELETON; THERAPY