Quantification of the reproducibility of the positioning in patients that receive radiotherapy with immobilization devices for treatments with VMAT using DRR and CBCT
Creators
- 1. ALIADA, Oncologia Integral, Av. Jose Galvez Barrenechea 1044, San Isidro, Lima 27 (Peru)
Description
The technological advances and the introduction of digital and computer systems to the treatment equipment s have contributed significantly in the precision when is necessary to deliver and distributing radiation dose in the planning volume where is located the tumor, besides also considering the healthy organs and tissues or in risk. For this treatment modality is necessary take into account the great importance that has the positioning, and immobilization and its reproducibility, making use of appropriate and personalized accessories that guarantee the bigger possible precision when the images are compared of before and after the treatment. For this study positioning data of 34 patients were quantified, which were treated with Volumetric Modulated Arc Therapy (VMAT) for the period between May to November of 2013. Of the patients 16 were treated in head and neck and 18 of prostate and abdomen. In all cases of head and neck treatment with VMAT immobilizer meshes were used that hold until the patient's neck, and in the cases of prostate and abdomen was used an immobilizer device under the knees and the ankles. All the cases were re-positioning using positioning techniques with Digitally Reconstructed Radiograph images (DRR) with acquisition modality Kv/Kv and Cone Beam the corrections and monitoring were carried out daily. Variations existed during the treatments that oscillate of 1-2 mm in the head and neck cases; and 2-4 mm in prostate and abdomen, these variations are necessary to quantify them in pro of the reproducibility in the patients positioning that receive radiotherapy and use immobilization device. (Author)
Files
46021479.pdf
Files
(323.6 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:2f98f0d1926870988b1a4fe91bbff909
|
323.6 kB | Preview Download |
Additional details
Additional titles
- Original title (Spanish)
- Cuantificacion de la reproducibilidad del posicionamiento en pacientes que reciben radioterapia con dispositivos de inmovilizacion para tratamientos con VMAT utilizando DRR y CBCT
Publishing Information
- Publisher
- Sociedad Mexicana de Irradiacion y Dosimetria
- Imprint Place
- Mexico, D. F. (Mexico)
- Imprint Pagination
- 9 p.
- Report number
- INIS-MX--2829
Conference
- Title
- 14. International Symposium on Solid State Dosimetry
- Original Conference Title
- 14. Conferencia Internacional sobre Dosimetria de Estado Solido
- Dates
- 13-16 Apr 2014
- Place
- Cusco (Peru)
INIS
- Country of Publication
- Mexico
- Country of Input or Organization
- Mexico
- INIS RN
- 46021479
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ABDOMEN; ACCURACY; ANIMAL TISSUES; BEAMS; BONE JOINTS; COMPARATIVE EVALUATIONS; CONES; CORRECTIONS; DIGITAL SYSTEMS; EQUIPMENT; HEAD; IMAGES; MONITORING; NECK; NEOPLASMS; PATIENTS; PLANNING; PROSTATE; RADIATION DOSES; RADIOTHERAPY
- Descriptors DEC
- BODY; DISEASES; DOSES; EVALUATION; GLANDS; MALE GENITALS; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; SKELETON; THERAPY
Optional Information
- Funding organization
- Organizacion Panamericana de la Salud, Washington D. C. (United States); Universidad Nacional de San Antonio de Abad del Cusco, Cusco (Peru); Instituto Peruano de Energia Nuclear, Lima (Peru); Elekta AB (Sweden); RadPro International GmbH (Germany); ThermoFisher Scientific, Inc. (United States); Varian Medical Systems (United States)