Published November 2017 | Version v1
Journal article

Estimation of the cumulative exposure frequency and cumulative effective dose of diagnostic medical radiation in the Korean population from 2002 to 2010

  • 1. Department of Radiology, Dae-Jeon SUN General Hospital, Dae-Jeon (Korea, Republic of)
  • 2. Chungbuk Regional Cardiocerebrovascular Center, Chungbuk National University Hospital, Cheong-ju (Korea, Republic of)
  • 3. Department of Radiation Oncology, College of Medicine, Chungbuk National University, Cheong-ju (Korea, Republic of)
  • 4. Department of Health Informatics and Management, College of Medicine, Chungbuk National University, Cheong-ju (Korea, Republic of)
  • 5. Center for Health Promotion/Department of Family Medicine, Seoul National University Hospital, Seoul (Korea, Republic of)
  • 6. Division of Cardiovascular and Rare Disease, Center for Biomedical Science, Korea National Institute of Health, Cheong-ju (Korea, Republic of)
  • 7. College of Medicine/Graduate School of Health Science Business Convergence, Chungbuk National University, Cheong-ju (Korea, Republic of)

Description

Along with increase in the frequency and exposure dose from the diagnostic medical radiation procedures, the public's interest in radiation exposure has also been growing. In this study, in order to estimate the Cumulative Exposure Frequency and the cumulative effective dose of diagnostic medical radiation in the Korean population, we included 680 diagnostic medical radiation procedure codes of the Health Insurance Review and Assessment Service's health insurance medical expenses data and adopted the effective dose data from the 2008 report of the United Nations Scientific Committee on the Effects of Atomic Radiation. We combined the data of one million individuals in the national sample cohort database (2002-10) of the National Health Insurance Service. The results revealed that 93.2% (917 972) of the subjects were exposed to diagnostic medical radiation at least once in the past nine years, and the Cumulative Exposure Frequency was 17 286.4 per 1000 individuals with a cumulative effective dose of 5.7 (±17.8) mSv per person. Additionally, 93.1% (854 480) of the subjects had a cumulative effective dose less than 20 mSv, and 0.7% (6139) had a dose that exceeded 100 mSv (extreme), showing that the dosage level was mostly low. However, the number of individuals whose exposure exceeded 100 mSv/y increased 28-fold, from 18 in 2002 to 500 in 2010. In addition, the size of increase also grew each year, suggesting that cancer occurrence due to diagnostic medical radiation may have also increased. In order determine the causal relationship between cancer occurrence and diagnostic medical radiation and setup a guideline for exposure, it is necessary to monitor individual cumulative exposure doses nationwide and follow up on heavily exposed individuals for an extended period of time. (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1093/rpd/ncw382

Additional details

Identifiers

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
176
Journal Issue
3
Journal Page Range
p. 203-210
ISSN
0144-8420

Optional Information

Notes
23 refs.