Published 1987 | Version v1
Book

Radon in houses due to radon in potable water

  • 1. Dept. of Physics, Univ. of Maine, Orono, ME (USA)

Description

Radon concentration in the air of 10 houses has been measured as a function of water use and meterological parameters such as barometric pressure, wind velocity and direction, indoor and outdoor temperature, and rainfall. Results of calibrations and data collected in winter, spring, fall, and summer are given for selected houses. Average values of radon concentration in air are from 0.80 to 77 rhoCi/1. Water use average ranges from 70 to 240 gal/day. Average potential alpha energy concentrations in these houses range from 0.02 to 1.6 working levels. The radon level due to water use ranges from 0 to 36% of the house radon from soil and water combined. The radon level change due to use of a filter on the water supply shows a 60% reduction in radon in the house. Conclusions are that water radon can be a major fraction of the radon in houses. The ratio of airborne radon concentration due to water use to the radon concentration in water is 4.5 x 10/sup -5/ - 13 x 10/sup -5/

Additional details

Publishing Information

Publisher
American Chemical Society.
Imprint Place
Washington, DC (USA)
ISBN
0-8412-1015-2
Imprint Title
Radon and its decay products: Occurrence, properties, and health effects
Journal Page Range
p. 30-41.

Conference

Title
191. American Chemical Society national meeting.
Dates
13-18 Apr 1986.
Place
New York, NY (USA).