Treatment Planning Study to Determine Potential Benefit of Intensity-Modulated Radiotherapy Versus Conformal Radiotherapy for Unresectable Hepatic Malignancies

  • 1. Radiation Medicine Program and Department of Radiation Oncology, Princess Margaret Hospital, University of Toronto, Toronto, ON (Canada)

Description

Purpose: To compare intensity-modulated radiotherapy (IMRT) with conformal RT (CRT) for hypofractionated isotoxicity liver RT and explore dose escalation using IMRT for the same/improved nominal risk of liver toxicity in a treatment planning study. Methods and Materials: A total of 26 CRT plans were evaluated. Prescription doses (24-54 Gy within six fractions) were individualized on the basis of the effective liver volume irradiated maintaining ≤5% risk of radiation-induced liver disease. The dose constraints included bowel (0.5 cm3) and stomach (0.5 cm3) to ≤30 Gy, spinal cord to ≤25 Gy, and planning target volume (PTV) to ≤140% of the prescribed dose. Two groups were evaluated: (1) PTV overlapping or directly adjacent to serial functioning normal tissues (n = 14), and (2) the liver as the dose-limiting normal tissue (n = 12). IMRT plans using direct machine parameter optimization maintained the CRT plan beam arrangements, an estimated radiation-induced liver disease risk of 5%, and underwent dose escalation, if all normal tissue constraints were maintained. Results: IMRT improved PTV coverage in 19 of 26 plans (73%). Dose escalation was feasible in 9 cases by an average of 3.8 Gy (range, 0.6-13.2) in six fractions. Three of seven plans without improved PTV coverage had small gross tumor volumes (≤105 cm3) already receiving 54 Gy, the maximal prescription dose allowed. In the remaining cases, the PTV range was 9.6-689 cm3; two had overlapped organs at risk; and one had four targets. IMRT did not improve these plans owing to poor target coverage (n = 2) and nonliver (n = 2) dose limits. Conclusion: Direct machine parameter optimization IMRT improved PTV coverage while maintaining normal tissue tolerances in most CRT liver plans. Dose escalation was possible in a minority of patients

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ijrobp.2008.06.1496

Additional details

Identifiers

DOI
10.1016/j.ijrobp.2008.06.1496;
PII
S0360-3016(08)02502-9;

Publishing Information

Journal Title
International Journal of Radiation Oncology, Biology and Physics
Journal Volume
72
Journal Issue
2
Journal Page Range
p. 582-588
ISSN
0360-3016
CODEN
IOBPD3

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
40007192
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
CARCINOMAS; DOSE LIMITS; IRRADIATION; LIVER; OPTIMIZATION; PLANNING; RADIATION DOSES; RADIOTHERAPY; SPINAL CORD; STOMACH; TOXICITY
Descriptors DEC
BODY; CENTRAL NERVOUS SYSTEM; DIGESTIVE SYSTEM; DISEASES; DOSES; GASTROINTESTINAL TRACT; GLANDS; MEDICINE; NEOPLASMS; NERVOUS SYSTEM; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; SAFETY STANDARDS; STANDARDS; THERAPY