A comparison of specific effective energies values obtained for some radioactive element using 3 different decay data banks
Creators
- 1. Instituto de Radioprotecao e Dosimetria (IRD), Rio de Janeiro, RJ (Brazil)
Description
The Specific Effective Energies (SEE) are the dose equivalents received by each of the body organs (targets organs) per nuclear transformation of a radionuclide deposited in an organ or tissue (source organ) after an intake of this isotope. The SEE values were calculated on basis of the dosimetric concepts of Publication 30 of the International Comission on Radiological Protection (ICRP). The results were evaluated using two of the three most known decay data banks. This study shows considerables discrepancies in the evaluation of the SEE values for some radionuclides. In theses cases it is recommended the use of the most complete and detailed decay data bank to perform the SEE calculations. (author)
Availability note (English)
Available from the Library of the Comissao Nacional de Energia Nuclear, RJ, Brazil.Abstract (Portuguese)
As Energias Especificas Efetivas (EEEs) sao as doses equivalentes recebidas pelos orgaos do corpo (orgaos alvos) a cada transformacao nuclear de um radionuclideo depositado em um determinado orgao ou tecido (orgao fonte) de um individuo contaminado internamente por material radioativo. Seus valores foram calculados com base no modelo dosimetrico apresentado na publicacao No. 30 da International Comission on Radiological Protection (ICRP). Observa-se porem, quando se calcula as EEEs utilizando-se os bancos de dados de energias de decaimento mais difundidos na literatura, que os resultados obtidos com os dados de cada um deles, ao serem comparados entre si, mostram haver discrepancias signicativas para alguns nuclideos. Nesses casos aconselha-se a utilizacao do banco de dados mais completo no calculo das EEEs. (autor)Additional details
Additional titles
- Original title (Portuguese)
- Comparacao dos valores das energias especificas efetivas obtidos para alguns elementos radioativos usando-se 3 bancos de dados diferentes
Publishing Information
- Imprint Pagination
- 11 p.
Conference
- Title
- 3. General Brazilian Congress of Nuclear Energy.
- Dates
- 22-27 Jul 1990.
- Place
- Rio de Janeiro, RJ (Brazil).
INIS
- Country of Publication
- Brazil
- Country of Input or Organization
- Brazil
- INIS RN
- 21093842
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference, Numerical Data, Non-conventional Literature
- Descriptors DEI
- D CODES; DOSE EQUIVALENTS; ELEMENTS; I CODES; ORGANS; PERSONNEL DOSIMETRY; STATISTICAL DATA
- Descriptors DEC
- BODY; COMPUTER CODES; DATA; DOSIMETRY; INFORMATION; NUMERICAL DATA