Inter-observer variation in masked and unmasked images for quality evaluation of clinical radiographs
Creators
- 1. Dept. of Radiation Physics, Malmoe Univ. Hospital, SE-205 02 Malmoe (Sweden)
- 2. Dept. of Radiology, Malmoe Univ. Hospital, SE-205 02 Malmoe (Sweden)
- 3. Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, SE-413 45 Goeteborg (Sweden)
- 4. Dept. of Radiation Physics, Linkoeping Univ., SE-581 85 Linkoeping (Sweden)
- 5. Dept. of Medical Physics and Biomedical Engineering, Sahlgrenska Univ. Hospital, SE-413 45 Goeteborg (Sweden)
Description
Purpose: To investigate the influence of masking on the inter-observer variation in image quality evaluation of clinical radiographs of chest and lumbar spine. Background: Inter-observer variation is a big problem in image quality evaluation since this variation is often much bigger than the variation in image quality between, for example, two radiographic systems. In this study, we have evaluated the effect of masking on the inter-observer variation. The idea of the masking was to force every observer to view exactly the same part of the image and to avoid the effect of the overall 'first impression' of the image. A discussion with a group of European expert radiologists before the study indicated that masking might be a good way to reduce the inter-observer variation. Methods: Five chest and five lumbar spine radiographs were collected together with detailed information regarding exposure conditions. The radiographs were digitised with a high-performance scanner and five different manipulations were performed, simulating five different exposure conditions. The contrast, noise and spatial resolution were manipulated by this method. The images were printed onto the film and the individual masks were produced for each film, showing only the parts of the images that were necessary for the image quality evaluation. The quality of the images was evaluated on ordinary viewing boxes by a large group of experienced radiologists. The images were examined with and without the masks with a set of image criteria (if fulfilled, 1 point; and not fulfilled, 0 point), and the mean score was calculated for each simulated exposure condition. Results: The results of this study indicate that - contrary to what was supposed - the inter-observer variation increased when the images were masked. In some cases, especially for chest, this increase was statistically significant. Conclusions: Based on the results of this study, image masking in studies of fulfilment of image criteria cannot be recommended. (authors)
Availability note (English)
Available from doi: http://dx.doi.org/10.1093/rpd/nch527Additional details
Identifiers
- DOI
- 10.1093/rpd/nch527;
Publishing Information
- Journal Title
- Radiation Protection Dosimetry
- Journal Volume
- 114
- Journal Issue
- 1-3
- Journal Page Range
- p. 62-68
- ISSN
- 0144-8420
Conference
- Title
- 2. Malmoe Conference on Medical X-Ray Imaging - Optimisation strategies in medical X-ray imaging
- Dates
- 23-25 Apr 2004
- Place
- Malmoe (Sweden)
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- France
- INIS RN
- 44035767
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CHEST; EVALUATION; FILMS; HUMAN POPULATIONS; IMAGE PROCESSING; IMAGES; MASKING; NOISE; PERFORMANCE; SIMULATION; SPATIAL RESOLUTION; VARIATIONS; VERTEBRAE
- Descriptors DEC
- BODY; ORGANS; POPULATIONS; PROCESSING; RESOLUTION; SKELETON
Optional Information
- Notes
- 13 refs