Description

The relation between operational quantities and risk quantities in radiation protection is discussed. Measurements made in the operational quantities ambient and personal dose equivalent, as defined by ICRU, are understood to provide and upper bound for the limits on radiological risk as recommended in Publication 60 of ICRP. These limits are actually expressed in effective dose, a quantity that is different from the previously used quantity effective dose equivalent. (author). 19 refs, 5 figs

Part of:
Intercomparison of radiation dosimeters for individual monitoring

Additional details

Publishing Information

Imprint Title
Intercomparison of radiation dosimeters for individual monitoring
Imprint Pagination
231 p.
Journal Page Range
p. 87-96.
ISSN
1011-4289
Report number
IAEA-TECDOC--704

INIS

Country of Publication
International Atomic Energy Agency (IAEA)
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
24056950
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Descriptors DEI
CALIBRATION; DOSE EQUIVALENTS; DOSE LIMITS; OCCUPATIONAL EXPOSURE; PERSONNEL DOSIMETRY; RADIATION DOSES; RADIATION PROTECTION
Descriptors DEC
DOSIMETRY; SAFETY STANDARDS; STANDARDS