Published 1980 | Version v1
Journal article

Corrosion of steel tendons used in prestressed concrete pressure vessels

  • 1. Oak Ridge National Lab., TN

Description

The corrosion behavior of a high-strength steel [Specifications for Uncoated Seven-Wire-Stress-Relieved Strand for Prestressed Concrete (ASTM A 416-74, Grade 270)], typical of those used as tensioning tendons in prestressed concrete pressure vessels was measured in several corrosive environments. The protection obtained by coating the steel with two commercial petroleum-base greases or with Portland cement grout was evaluated. The few reported incidents of prestressing steel failures in concrete pressure vessels used for containment of nuclear reactors were reviewed. The susceptibility of the steel to stress corrosion cracking and hydrogen embrittlement and its general corrosion rate were determined in several salt solutions. Wires coated with the greases and grout were soaked for long periods in the same solutions and changes in their mechanical properties were subsequently determined. All three coatings appeared to give essentially complete protection; however, flaws in the grease coatings could be detrimental, and flaws or cracks less than 1-mm-wide (0.04 in.) in the grout were without effect

Additional details

Publishing Information

Journal Title
Am. Soc. Test. Mater., Spec. Tech. Publ.
Journal Issue
no.713
Series
Am. Soc. Test. Mater., Spec. Tech. Publ.
ISSN
0066-0558