Published 1960 | Version v1
Report Open

Calibration of langmuir probes by a microwave method

  • 1. Commissariat a l'Energie Atomique, Saclay (France).Centre d'Etudes Nucleaires

Description

Measurements of the electronic density of a plasma between 106 and 108 e/cm3, made by the Langmuir probe and by resonance frequency shift of a cavity are compared. (author)

Availability note (English)

Available from INIS in electronic form

Abstract (French)

On compare les mesures de la densite electronique d'un plasma peu dense 106 < ne < 108 e/cm3, par sonde de Langmuir et par glissement de la frequence de resonance d'une cavite contenant le plasma. (auteur)

Files

38102017.pdf

Files (236.0 kB)

Name Size Download all
md5:773011b50823bd5922df4c09de67e855
236.0 kB Preview Download

Additional details

Additional titles

Original title (French)
Etalonnage des sondes de langmuir par une methode hyperfrequence

Publishing Information

Imprint Pagination
18 p.
Report number
CEA-R--1440

Optional Information

Notes
5 refs.