Published May 1982 | Version v1
Journal article

Linear analysis of secundary pumps of the Super Phenix reactor

  • 1. CISI, Paris (France)

Description

Three types of dynamic analysis are carried out: i) search for frequency and eigen modes, ii) response to a harmonic sollicitation, iii) response to seismic waves. Computation is realized with the computer code CASTEM made by the CEA and the CISI. It allows computation of revolution structures under loading even not axisymmetrical with or without an internal liquid and connection of substructures (linear analysis). Some informations are given, in this paper, on methods and algorithms used in CASTEM, Models used are described and main results are given

Abstract (French)

On effectue trois types d'analyse dynamique: recherche des frequences et modes propres, reponse a une sollicitation harmonique, reponse a un seisme de base ou majore. Tous les calculs ont ete effectues a l'aide du code de calcul de structures CASTEM concu par le CEA et la CISI. Ce logiciel permet notamment le calcul des structures de revolution sous chargement eventuellement non axisymetrique avec prise en compte ou non d'un liquide interne ainsi que le raccordement des sous-structures en dynamique (synthese modale). Dans ce papier on donne quelques informations sur les methodes et algorithmes utilises dans CASTEM puis on decrit les modeles utilises et on fournit quelques resultats

Additional details

Additional titles

Original title (French)
Utilisation de la methode de synthese modale pour l'etude des pompes secondaires de Super Phenix
Augmented title (English)
CASTEM code

Publishing Information

Journal Title
Mec., Mater., Electr.
Journal Issue
no.389-391
Series
Mec., Mater., Electr.
ISSN
0025-6439