Published February 1996 | Version v1
Report Open

Fast charge exchange spectroscopy using a Fabry-Perot spectrometer in the JIPP TII-U tokamak

Description

A new charge exchange spectroscopic technique using a Fabry-Perot spectrometer has been developed to increase the photon flux at the detector and improve the time resolution of ion temperature and plasma rotation velocity measurements. The spectral resolution is obtained by arranging two dimensional fiber optics and a two dimensional detector at the focal plane of a coupled lens located on both sides of a Fabry-Perot spectrometer. The effective finesse of the Fabry-Perot interferometer in this system is 14. The time evolution of the ion temperature is obtained with a time resolution of 125 μs and with the spatial resolution of 3 cm (8 channels). (author)

Availability note (English)

MF available from INIS under the Report Number.

Files

27067126.pdf

Files (418.6 kB)

Name Size Download all
md5:84c69eeacddd067f98b39e36f8ece561
418.6 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
18 p.
Report number
NIFS--401