Published January 1996 | Version v1
Miscellaneous Open

Comparison of the MCNP calculated and measured radiation field quantities near the RB reactor

  • 1. Vinca Institute of Nuclear sciences, Belgrade (Yugoslavia)

Description

The RB experimental reactor has operated at Vinca Institute of nuclear sciences since the end of April 1958. In this paper, neutron and gamma ray spectra and corresponding dose quantities near the reactor, calculated by using the MCNP code, are compared to the measured values during the Third International Intercomparison experiment on nuclear dosimetry carried out at the RB reactor. in 1973. Discrepancies in the correlation declared power of the reactor-dose rates are found. Good agreements are obtained between measured and calculated neutron and gamma-ray spectra, and corresponding absorbed doses in air, but only after the reactor declared power is multiplied by a correction factor, determined in this study

Availability note (English)

Available from INIS in electronic form; Also available from the Institute of nuclear sciences Vinca

Files

39095650.pdf

Files (422.8 kB)

Name Size Download all
md5:9d1fadbce30ae56b1c0d482996db6025
422.8 kB Preview Download

Additional details

Publishing Information

Publisher
Health Physics, the radiation safety journal
Imprint Pagination
v. 77(3) 7 p.
Report number
INIS-RS--1437

Optional Information

Notes
17 refs., 6 figs., 2 tabs.