Published September 1995 | Version v1
Report Restricted

A demonstration of beam intensity modulation without loss of charge

Description

The large acceptance and the simplicity of H- extraction makes practical unusual modes of cyclotron operation. RF equipment, initially installed for H- extraction at TRIUMF, has been used to modulate the beam intensity at the extraction radius. This equipment consists of a 92 MHz, 150 kV cavity (AAC) and an RFD (11.5 MHz, 20 kV). The AAC augments the acceleration provided by the main 23 MHz, RF system; the RFD excites radial betatron oscillations. These devices may be operated at frequencies slightly different from their design multiple; their effect then beats with the main RF. In this mode the AAC, for example, alternately reduces the rate of acceleration, thus increasing the overlap of turns, then enhances it, sweeping the clustered turns onto a probe or foil. Operating the AAC or RFD in this manner gathers the bulk of the charge into peaks a few microseconds wide and spaced between 6 and 50 micros. Changing the frequency offset alters the spacing. The peak to valley ratio was 23:1 and all beam was transmitted to the extraction radius

Availability note (English)

MF available from INIS under the Report Number; Also available from OSTI as DE96002146; NTIS.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
4 p.
Report number
TRI-PP--95-74

Conference

Title
14. international conference on cyclotrons and their applications.
Dates
8-13 Oct 1995.
Place
Cape Town (South Africa).

Optional Information