Published September 1988 | Version v1
Report Open

Gas transfer system

Description

The state of work on the Vivitron gas transfer system and the system functions are summarized. The system has to: evacuate the Vivitron reservoir; transfer gas from storage tanks to the Vivitron; recirculate gas during operation; transfer gas from the Vivitron to storage tanks; and assure air input. The system is now being installed. Leak alarms are given by SF6 detectors, which set off a system of forced ventilation. Another system continuously monitors the amount of SF6 in the tanks

Availability note (English)

MF available from INIS under the Report Number.

Abstract (French)

L'etat d'avancement du systeme de transfert de gaz pour le Vivitron, et les fonctions demandees au systeme sont presentes. Les fonctions sont: mise sous vide du reservoir Vivitron; transfert du gaz des reservoirs de stockage vers le Vivitron; recirculation du gaz en cours de fonctionnement; transfert du gaz du Vivitron vers les reservoirs de stockage; et rentree d'air. L'ensemble est en cours de mise en place. Des detecteurs de SF6 doivent alerter en cas de fuite et declencher un systeme de ventilation forcee. Un autre systeme permet de verifier en permanence la quantite de SF6 presente dans les reservoirs

Files

20069098.pdf

Files (160.2 kB)

Name Size Download all
md5:4a34d51f93596225871268d7dc9963d1
160.2 kB Preview Download

Additional details

Additional titles

Original title (French)
Systeme de Transfert de Gaz

Publishing Information

Imprint Pagination
8 p.
Report number
CRN-VIV--59