Effect of 11C-Methionine-Positron Emission Tomography on Gross Tumor Volume Delineation in Stereotactic Radiotherapy of Skull Base Meningiomas
Creators
- 1. Department of Radiation Oncology, Klinikum rechts der Isar, Technical University of Munich, Munich (Germany)
- 2. Department of Nuclear Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich (Germany)
- 3. Department of Radiation Oncology, University of Freiburg, Freiburg (Germany)
- 4. Department of Nuclear Medicine, University of Freiburg, Freiburg (Germany)
Description
Purpose: To evaluate the effect of trimodal image fusion using computed tomography (CT), magnetic resonance imaging (MRI) and 11C-methionine positron emission tomography (MET-PET) for gross tumor volume delineation in fractionated stereotactic radiotherapy of skull base meningiomas. Patients and Methods: In 32 patients with skull base meningiomas, the gross tumor volume (GTV) was outlined on CT scans fused to contrast-enhanced MRI (GTV-MRI/CT). A second GTV, encompassing the MET-PET positive region only (GTV-PET), was generated. The additional information obtained by MET-PET concerning the GTV delineation was evaluated using the PET/CT/MRI co-registered images. The sizes of the overlapping regions of GTV-MRI/CT and GTV-PET were calculated and the amounts of additional volumes added by the complementing modality determined. Results: The addition of MET-PET was beneficial for GTV delineation in all but 3 patients. MET-PET detected small tumor portions with a mean volume of 1.6 ± 1.7 cm3 that were not identified by CT or MRI. The mean percentage of enlargement of the GTV using MET-PET as an additional imaging method was 9.4% ± 10.7%. Conclusions: Our data have demonstrated that integration of MET-PET in radiotherapy planning of skull base meningiomas can influence the GTV, possibly resulting in an increase, as well as in a decrease
Availability note (English)
Available from http://dx.doi.org/10.1016/j.ijrobp.2008.02.058Additional details
Identifiers
- DOI
- 10.1016/j.ijrobp.2008.02.058;
- PII
- S0360-3016(08)00425-2;
Publishing Information
- Journal Title
- International Journal of Radiation Oncology, Biology and Physics
- Journal Volume
- 72
- Journal Issue
- 4
- Journal Page Range
- p. 1161-1167
- ISSN
- 0360-3016
- CODEN
- IOBPD3
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 40047649
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; CARBON 11; COMPUTERIZED TOMOGRAPHY; IMAGES; METHIONINE; NEOPLASMS; NMR IMAGING; PATIENTS; POSITRON COMPUTED TOMOGRAPHY; RADIOTHERAPY; SKULL
- Descriptors DEC
- AMINO ACIDS; BETA DECAY RADIOISOTOPES; BETA-PLUS DECAY RADIOISOTOPES; BODY; CARBON ISOTOPES; CARBOXYLIC ACIDS; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; DISEASES; DRUGS; EMISSION COMPUTED TOMOGRAPHY; EVEN-ODD NUCLEI; ISOTOPES; LIGHT NUCLEI; LIPOTROPIC FACTORS; MEDICINE; MINUTES LIVING RADIOISOTOPES; NUCLEAR MEDICINE; NUCLEI; ORGANIC ACIDS; ORGANIC COMPOUNDS; ORGANIC SULFUR COMPOUNDS; ORGANS; RADIOISOTOPES; RADIOLOGY; SKELETON; THERAPY; TOMOGRAPHY
Optional Information
- Copyright
- Copyright (c) 2008 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.