Report on measurements at the pump Avala - Annex 7

Creators

  • 1. Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Serbia)

Description

Visual inspection and measuring results have shown that the surface of the upper pump bearing is much more worn-out than the lower radial bearing. This has proved that most of the cobalt (contained in the stellite alloy) came from the upper pump bearings. It could be stated that about 60 grams of cobalt from the upper pump bearings could come into the coolant system

Abstract (Serbian)

Na osnovu vizuelnog pregleda i rezultata merenja potvrdjeno je da je sklop gornjeg lezista pumpe mnogo vise pohaban nego donje radijalno leziste. Ovo je potvrdilo da je najvise kobalta (sadrzanog u leguri stelita) poreklom iz gornjih lezista pumpi. Moze se konstatovati da je iz gornjih lezista pumpi u sistem dospelo oko 60 grama kobalta

Files

41124192.pdf

Files (318.0 kB)

Name Size Download all
md5:1f59e770a9afb12c19818785c4564cc7
318.0 kB Preview Download
Part of:
Heavy water pumps

Additional details

Additional titles

Original title (Serbian)
Prilog 7 - Izvestaj o merenjima na pumpi Avala

Publishing Information

Imprint Place
Beograd-Vinca (Serbia)
Imprint Title
Heavy water pumps
Imprint Pagination
149 p.
Journal Page Range
6 p.
Report number
INIS-CS--0096

Optional Information

Notes
This record replaces 37052913 Imprint:6 tabs, 6 figs, 7 refs;Pumpe D_2O
Secondary number(s)
RA--214/R3/P3/56/07