Published October 1987 | Version v1
Journal article

A Josephson array voltage standard at 10 V

  • 1. Electromagnetic Technology Div., National Bureau of Standards, Boulder, CO (USA)

Description

The technology of Josephson voltage standards has been extended to an array of 14 184 junctions which is capable of generating over 150 000 quantized voltage levels spanning the range from -12 to +12V. This makes possible the direct calibration of 10-V Zener reference standards without the use of a voltage divider

Additional details

Publishing Information

Journal Title
IEEE Electron Device Lett.
Journal Volume
EDL-8
Journal Issue
10
Series
IEEE Electron Device Lett.
Journal Page Range
449-450
ISSN
0741-3106
CODEN
EDLED

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
19086367
Subject category
S71: CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS;
Descriptors DEI
CALIBRATION; ELECTRIC POTENTIAL; JOSEPHSON JUNCTIONS; JUNCTION DIODES; PERFORMANCE; SPECIFICATIONS; VOLTAGE REGULATORS
Descriptors DEC
SEMICONDUCTOR DEVICES; SEMICONDUCTOR DIODES; SEMICONDUCTOR JUNCTIONS