Published March 28, 1975 | Version v1
Report Restricted

Implications of shorter cells in PEP

Description

Further studies on the beam-stay-clear requirements in PEP led to the conclusion that the vertical aperture needed to be enlarged. There are two main reasons for that: Observations at SPEAR indicate that the aperture should be large enough for a fully coupled beam. Full coupling of the horizontal and vertical betatron oscillations occurs not only occasionally when the energy, tune or betatron function at the interaction point is changed but also due to the beam/endash/beam effect of two strong colliding beams. The second reason for an increased aperture requirement is the nonlinear perturbation of the particle trajectories by the sextupoles. This perturbation increases a fully coupled beam by another 50% to 80%. Both effects together with a +-5 mm allowance for closed orbit perturbation result in a vertical beam-stay-clear in the bending magnets of +-4.8 to +-5.6 cm, compared to the present +-2.0 cm. This beam-stay-clear, together with additional space for vacuum chamber, etc., leads to very costly bending magnets. In this note, a shorter cell length is proposed which would reduce considerably the vertical beam-stay-clear requirements in the bending magnets. 7 figs

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A03/MF A01; 1 as DE88014852.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
14 p.
Report number
SLAC-PEP-NOTE--117

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
20008616
Subject category
S43: PARTICLE ACCELERATORS;
Descriptors DEI
BEAM BENDING MAGNETS; BEAM CURRENTS; BEAM DYNAMICS; BEAM LUMINOSITY; BETATRON OSCILLATIONS; PEP STORAGE RINGS; TRAJECTORIES
Descriptors DEC
CURRENTS; DYNAMICS; EQUIPMENT; MAGNETS; MECHANICS; OSCILLATIONS; STORAGE RINGS

Optional Information

Notes
Portions of this document are illegible in microfiche products.