Published June 2013 | Version v1
Miscellaneous Open

Test tools of physics radiography children as a support for safety radiation and safety patients

  • 1. Politeknik Kesehatan, Kemenkes, Jl. Tirto Agung, Pedalangan, Banyumanik, Semarang 50239 (Indonesia)

Description

Radiographic examination of the thorax children aged 1-3 years have a high sufficiently failure. This failure is caused by the movement and difficulty positioning the patient, resulting in the risk of repeat radiographs to patient safety particularly unnecessary radiation risks. It is therefore necessary to develop research on children design fixation devices. This research aims to create a design tool fixation on radiographs children to support radiation safety and patient safety. This research is a descriptive exploratory approach to tool design. The independent variables were the design tools, variable tool function test results, and radiographic variables controlled thorax. The procedure is done by designing data collection tools, further trials with 20 samples. Processing and analysis of data is done by calculating the performance assessment tool scores with range 1-3. The results showed that the design tool of fixation in the form of standard radiographic cassette equipped with chairs and some form of seat belt fixation. The procedure uses a tool fixation is routine radiographic follow thorax child in an upright position. Function test results aids fixation is to have an average score of 2.66, which means good. While the test results for each component, the majority of respondents stated that the reliability of the device is quite good with a score of 2.45 (60 %), convenience tool with a score of 2.60 (70 %), quality of the radiographs did not incontinence of the thorax radiograph with a score 2.55 (85 %), the child protection (security) with a score of 2.70 (70 %), good design aesthetic design with a score of 2.80 (80 %), addition of radiation from the others on the use of these tools do not need with a score of 2.80 (80 %), and there is no additional radiation due to repetitions with a score of 2.85 (90 %). (author)

Files

49042162.pdf

Files (432.6 kB)

Name Size Download all
md5:994d3b3871bc0f0eef560e7919b739c2
432.6 kB Preview Download
Part of:
Proceedings of the nuclear safety seminar, 2013: With the spirit of togetherness we improve the synergy of nuclear power control

Additional details

Additional titles

Original title (Indonesian)
Pengujian alat bantu fiksasi radiografi anak sebagai penunjang keselamatan radiasi dan keselamatan pasien

Publishing Information

Publisher
Nuclear Energy Regulatory Agency
Imprint Place
Jakarta (Indonesia)
Imprint Title
Proceedings of the nuclear safety seminar, 2013: With the spirit of togetherness we improve the synergy of nuclear power control
Imprint Pagination
426 p.
Journal Page Range
p. 38-49
ISSN
1412-3258
Report number
INIS-ID--75

Conference

Title
Nuclear safety seminar, 2013
Original Conference Title
Seminar keselamatan nuklir, 2013
Dates
19 Jun 2013
Place
Jakarta (Indonesia)

INIS

Country of Publication
Indonesia
Country of Input or Organization
Indonesia
INIS RN
49042162
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CHEST; CHILDREN; MACHINE TOOLS; PATIENTS; PERFORMANCE TESTING; POSITIONING; SAFETY; X-RAY RADIOGRAPHY
Descriptors DEC
AGE GROUPS; ANIMALS; BODY; EQUIPMENT; INDUSTRIAL RADIOGRAPHY; MAMMALS; MAN; MATERIALS TESTING; NONDESTRUCTIVE TESTING; PRIMATES; TESTING; TOOLS; VERTEBRATES

Optional Information

Notes
13 refs.; 13 tabs.; 6 figs. Imprint:Prosiding seminar keselamatan nuklir, 2013: Dengan semangat kebersamaan kita tingkatkan sinergi pengawasan tenaga nuklir