Test tools of physics radiography children as a support for safety radiation and safety patients
- 1. Politeknik Kesehatan, Kemenkes, Jl. Tirto Agung, Pedalangan, Banyumanik, Semarang 50239 (Indonesia)
Description
Radiographic examination of the thorax children aged 1-3 years have a high sufficiently failure. This failure is caused by the movement and difficulty positioning the patient, resulting in the risk of repeat radiographs to patient safety particularly unnecessary radiation risks. It is therefore necessary to develop research on children design fixation devices. This research aims to create a design tool fixation on radiographs children to support radiation safety and patient safety. This research is a descriptive exploratory approach to tool design. The independent variables were the design tools, variable tool function test results, and radiographic variables controlled thorax. The procedure is done by designing data collection tools, further trials with 20 samples. Processing and analysis of data is done by calculating the performance assessment tool scores with range 1-3. The results showed that the design tool of fixation in the form of standard radiographic cassette equipped with chairs and some form of seat belt fixation. The procedure uses a tool fixation is routine radiographic follow thorax child in an upright position. Function test results aids fixation is to have an average score of 2.66, which means good. While the test results for each component, the majority of respondents stated that the reliability of the device is quite good with a score of 2.45 (60 %), convenience tool with a score of 2.60 (70 %), quality of the radiographs did not incontinence of the thorax radiograph with a score 2.55 (85 %), the child protection (security) with a score of 2.70 (70 %), good design aesthetic design with a score of 2.80 (80 %), addition of radiation from the others on the use of these tools do not need with a score of 2.80 (80 %), and there is no additional radiation due to repetitions with a score of 2.85 (90 %). (author)
Files
49042162.pdf
Files
(432.6 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:994d3b3871bc0f0eef560e7919b739c2
|
432.6 kB | Preview Download |
Additional details
Additional titles
- Original title (Indonesian)
- Pengujian alat bantu fiksasi radiografi anak sebagai penunjang keselamatan radiasi dan keselamatan pasien
Publishing Information
- Publisher
- Nuclear Energy Regulatory Agency
- Imprint Place
- Jakarta (Indonesia)
- Imprint Title
- Proceedings of the nuclear safety seminar, 2013: With the spirit of togetherness we improve the synergy of nuclear power control
- Imprint Pagination
- 426 p.
- Journal Page Range
- p. 38-49
- ISSN
- 1412-3258
- Report number
- INIS-ID--75
Conference
- Title
- Nuclear safety seminar, 2013
- Original Conference Title
- Seminar keselamatan nuklir, 2013
- Dates
- 19 Jun 2013
- Place
- Jakarta (Indonesia)
INIS
- Country of Publication
- Indonesia
- Country of Input or Organization
- Indonesia
- INIS RN
- 49042162
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CHEST; CHILDREN; MACHINE TOOLS; PATIENTS; PERFORMANCE TESTING; POSITIONING; SAFETY; X-RAY RADIOGRAPHY
- Descriptors DEC
- AGE GROUPS; ANIMALS; BODY; EQUIPMENT; INDUSTRIAL RADIOGRAPHY; MAMMALS; MAN; MATERIALS TESTING; NONDESTRUCTIVE TESTING; PRIMATES; TESTING; TOOLS; VERTEBRATES
Optional Information
- Notes
- 13 refs.; 13 tabs.; 6 figs. Imprint:Prosiding seminar keselamatan nuklir, 2013: Dengan semangat kebersamaan kita tingkatkan sinergi pengawasan tenaga nuklir