First experience of evaluation of the impact of high-matrix size reconstruction in image quality in arterial CT runoff studies of the lower extremities
Creators
- 1. Department of Radiology, Duke University Health System, Box 3808, 2301 Erwin Road, 27110, Durham, NC (United States)
- 2. Siemens Healthineers, Malvern, PA (United States)
- 3. Department of Surgery, Duke University Health System, Box 3704, 2301 Erwin Road, 27110, Durham, NC (United States)
- 4. Department of Vascular Surgery, Duke University Health System, Durham, NC (United States)
Description
To determine whether image reconstruction with a higher matrix size improves image quality for lower extremity CTA studies. Raw data from 50 consecutive lower extremity CTA studies acquired on two MDCT scanners (SOMATOM Flash, Force) in patients evaluated for peripheral arterial disease (PAD) were retrospectively collected and reconstructed with standard (512 × 512) and higher resolution (768 × 768, 1024 × 1024) matrix sizes. Five blinded readers reviewed representative transverse images in randomized order (150 total). Readers graded image quality (0 (worst)-100 (best)) for vascular wall definition, image noise, and confidence in stenosis grading. Ten patients' stenosis scores on CTA images were compared to invasive angiography. Scores were compared using mixed effects linear regression. Reconstructions with 1024 × 1024 matrix were ranked significantly better for wall definition (mean score 72, 95% CI = 61-84), noise (74, CI = 59-88), and confidence (70, CI = 59-80) compared to 512 × 512 (wall = 65, CI = 53 × 77; noise = 67, CI = 52 × 81; confidence = 62, CI = 52 × 73; p = 0.003, p = 0.01, and p = 0.004, respectively). Compared to 512 × 512, the 768 × 768 and 1024 × 1024 matrix improved image quality in the tibial arteries (wall = 51 vs 57 and 59, p < 0.05; noise = 65 vs 69 and 68, p = 0.06; confidence = 48 vs 57 and 55, p < 0.05) to a greater degree than the femoral-popliteal arteries (wall = 78 vs 78 and 85; noise = 81 vs 81 and 84; confidence = 76 vs 77 and 81, all p > 0.05), though for the 10 patients with angiography accuracy of stenosis grading was not significantly different. Inter-reader agreement was moderate (rho = 0.5). Higher matrix reconstructions of 768 × 768 and 1024 × 1024 improved image quality and may enable more confident assessment of PAD. Higher matrix reconstructions of the vessels in the lower extremities can improve perceived image quality and reader confidence in making diagnostic decisions based on CTA imaging.
Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology (Internet)
- Journal Volume
- 33
- Journal Issue
- 12
- Journal Page Range
- p. 8745-8753
- ISSN
- 1432-1084
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 55019750
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; ARTERIES; BLOOD CIRCULATION; COMPARATIVE EVALUATIONS; COMPUTERIZED TOMOGRAPHY; DATA COMPILATION; FEMUR; IMAGE PROCESSING; IMAGE SCANNERS; LEGS; REGRESSION ANALYSIS; REVIEWS; SPATIAL RESOLUTION; VASCULAR DISEASES
- Descriptors DEC
- BLOOD VESSELS; BODY; CARDIOVASCULAR DISEASES; CARDIOVASCULAR SYSTEM; DATA; DATA PROCESSING; DIAGNOSTIC TECHNIQUES; DISEASES; DOCUMENT TYPES; EVALUATION; INFORMATION; LIMBS; MATHEMATICS; ORGANS; PROCESSING; RESOLUTION; SKELETON; STATISTICS; TOMOGRAPHY