Published February 1, 2005
| Version v1
Report
Performance of the G0 superconducting magnet system
Description
At the heart of the G0 Spectrometer is the toroidal superconducting magnet system (SMS). The SMS has been in use at Jefferson Lab since the fall of 2002. Experience with the operation and reliability of the magnet over that period is reported. Some measured performance parameters are compared with the magnet specification.
Additional details
Publishing Information
- Imprint Pagination
- vp.
- Report number
- JLAB-PHY--05-433
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 41097317
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Non-conventional Literature
- Descriptors DEI
- MAGNETS; PERFORMANCE; RELIABILITY; SPECTROMETERS; SUPERCONDUCTING MAGNETS
- Descriptors DEC
- ELECTRICAL EQUIPMENT; ELECTROMAGNETS; EQUIPMENT; MAGNETS; MEASURING INSTRUMENTS; SUPERCONDUCTING DEVICES
Optional Information
- Contract/Grant/Project number
- AC05-84ER40150
- Notes
- Paper compiled for PAVI04
- Funding organization