The purpose of the analog monitoring system (AMS) is to provide CEBAF operators the ability to monitor voltage signals from the RF control modules, beam loss monitors, and other dedicated systems from the accelerator services buildings with a 10 MHz (-1 dB), bandwidth. The signals are presented at the AMS receiving crate in the Machine Control Center (MCC). The system, when completed, will allow the operator to monitor any 4 signals from available channels in each location. At present, these locations provide 800 signals in each of the linacs, 16 signals in each of the arcs, 120 signals in the injector, and 16 signals in the beam switchyard. This provides a total capacity of 1768 signals, with an upgrade ability of 3740 total signal capacity

Availability note (English)

Available from Thomas Jefferson National Accelerator Facility, Newport News, VA (US)

Additional details

Publishing Information

Imprint Pagination
201 Kilobytes
Report number
CEBAF-PR--93-039

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
33054679
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Non-conventional Literature
Descriptors DEI
ANALOG SYSTEMS; BEAM MONITORS; CAPACITY; CEBAF ACCELERATOR; CONTROL SYSTEMS; MONITORING
Descriptors DEC
ACCELERATORS; LINEAR ACCELERATORS; MEASURING INSTRUMENTS; MONITORS

Optional Information

Contract/Grant/Project number
AC05-84ER40150
Funding organization
USDOE Office of Energy Research ER (United States)
Secondary number(s)
DOE/ER--40150-1923