Published December 2013 | Version v1
Journal article

The value of right lateral decubitus position to decrease artificial defect of cardiac anterior wall in 99Tcm-MIBI SPECT myocardial perfusion imaging for women

  • 1. Department of Nuclear Medicine, the First People's Hospital of Foshan (China)

Description

Objective: To explore the value of right lateral decubitus position MPI for differentiating myocardial perfusion defect from cardiac anterior wall attenuation artificial defect, caused by breast of woman. Methods: Forty-nine patients(average age (61.5±8.4) years) who had low likelihood of coronary artery disease and had perfusion defect in the anterior wall after exercise stress 99Tcm-MIBI MPI were included. All underwent supine and right lateral decubitus position during resting SPECT images. The myocardial perfusion SPECT images at left ventricle were reconstructed and were measured by Bull's-eye, based on the counts. Results from both supine position imaging and right lateral decubitus position imaging were compared. Paired t test was used to statistically analyse the data by SPSS 13.0. Results: Compared with supine position, the counts of the anterior, inferior, apex and lateral wall in right lateral decubitus position were significantly higher: (71.30±3.53)% vs (66.50±3.85)%, (70.06±4.45)% vs (65.44±4.16)%, (77.90±3.00)% vs (75.81±4.08)%,(79.30±2.26)% vs (72.60±3.87)% (t=6.731, 5.286, 3.555, 10.885, all P<0.01). The counts of septal wall were significantly lower ((66.60±3.98)% vs (70.06±4.51)%, t=-4.625, P<0.01) in right lateral decubitus position than that in supine position. Among the different regions of anterior wall, the counts of the anterior-middle ((76.40 ± 3.80)% vs (68.60 ± 4.76)%) and anterior-apex region ((77.10±3.24)% vs (69.00±3.54)%) were significantly higher (t=9.916, 8.870, both P<0.01) in right lateral decubitus position than those in supine position, but there was insignificance ((56.94±6.06)% vs (58.50±4.98)%, t=-1.493, P>0.05) at anterior-basal region. The artificial defect of different degrees in anterior wall was observed in all patients in supine position, 23 cases (46.9%, 23/49) showed artificial defect in the anterior-middle region and 16 cases (32.7%, 16/49) in the anterior-apex region. All artificial defect showed radioactive filling in right lateral position imaging, 12 cases(24.5%, 12/49) filled markedly and 32 cases(65.3%, 32/49) filled completely. Conclusions: The artificial defects caused by breast of woman mainly present in anterior-middle region and in anterior-apex region of the anterior wall in supine position imaging. The right lateral decubitus position imaging can markedly improve these artificial defects. (authors)

Additional details

Publishing Information

Journal Title
Chinese Journal of Nuclear Medicine and Molecular Imaging
Journal Volume
33
Journal Issue
6
Journal Page Range
p. 444-447
ISSN
2095-2848

Optional Information

Notes
1 figs., 1 tabs., 12 refs.